Napačna izbira? Nič za to! Izdelke lahko vrnete do 30 dni
Z darilnim bonom ne morete zgrešiti. Obdarovanec lahko v zameno za darilni bon izbere karkoli iz naše ponudbe.
Do 30 dni za vračilo
A unit trips. Frequency sags, ACE swings and contingency analysis flags an overload. Which number do you act on first, and what does it mean for the next fifteen minutes?
Operators are often taught from material written before mandatory reliability standards, organized markets and utility-scale solar, wind and battery plants. Formulas arrive without the decisions they drive, and the lessons of major disturbances stay inside long event reports.
This independent reference manual teaches power system operation as it is practiced in today's control room, through 228 worked operator calculations, 9 real grid-event case studies and a free interactive simulator. One fictional Teaching System runs through every example, so numbers carry from chapter to chapter.
Every calculation ends with what the number means on shift. Each worked example closes with an "Operator meaning" line that turns the result into a control-room decision, and every printed number was recomputed by an independent check. They run from ACE, frequency bias, CPS1 and the Balancing Authority ACE Limit to PTDF, LODF and OTDF flow shifts, reactive margin, load shed per stage and cold-load pickup.
Nine grid events, decision by decision. Each case study shows what the operator saw, the options and what happened, then what changed afterwards, from the 2003 Northeast blackout and the 1996 Western Interconnection separation to the June 2022 Odessa disturbance and the February 2021 and December 2022 winter storms.
A standards map for every section. A Standards Connection box in each chapter and an appendix map all 125 sections to the reliability standard families an operator uses, described in the book's own words.
Free Interactive Control-Room Simulator. A QR code inside the book opens a browser application for phone, tablet or computer on the same Teaching System: balance ACE through a load ramp, a schedule ramp and a unit trip; run N-1 contingency analysis and redispatch against normal and emergency ratings; then work an islanding event with underfrequency load shedding and a blackstart restoration.
Inside, you will learn to:
The book also holds 120 practice problems with full worked solutions, 36 full-color original figures, a formula sheet of all 113 numbered equations, a glossary of 184 operator terms and an index, across 12 chapters.
Who it is for: system operators and trainees at reliability coordinators, balancing authorities, transmission operators and generator operators, engineers moving into real-time operations, utility and system operator trainers, and electrical engineering students. If you are preparing for the NERC system operator certification examinations, it covers the operating knowledge those examinations draw on.
This is an independent reference manual. It is not affiliated with, authorized by or endorsed by NERC.
Open the book at the first unit trip, scan the QR code to run it yourself, and turn every number on the console into the decision it drives.
Pozdravljeni! Sem Libroamiko, vaš knjižni svetovalec.
Kako vam lahko pomagam?